Design Your Comfort System in 3D
Smith Climate · Tishomingo, MS
Heat pump
3–4 tons
2,000 sq ft
How this is figured Sources and assumptions
The planning size
Rule-of-thumb planning band. Not a load calculation. A Manual J load calculation sets the real size.
The band is conditioned square feet divided by a square-feet-per-ton range for your climate zone, nudged by insulation, windows, sun and ceiling height, then rounded to the half-ton sizes equipment comes in (1.5 to 5 tons). Above 5 tons it says likely two systems. One ton is 12,000 Btu per hour. Airflow is the nominal 400 CFM per ton figure.
| Climate zone | Sq ft per ton used |
|---|---|
| Zone 1 · Very hot | 400 to 600 |
| Zone 2 · Hot | 450 to 650 |
| Zone 3 · Warm | 500 to 700 |
| Zone 4 · Mixed | 550 to 750 |
| Zone 5 · Cool | 600 to 800 |
| Zone 6 · Cold | 650 to 850 |
| Zone 7 · Very cold | 700 to 900 |
- Insulation: older or leaky +15%, average no change, tight −15%.
- Windows: few −5%, average no change, lots of glass +10%.
- Sun: shaded −7%, average no change, full sun +8%.
- Ceilings: 8 ft no change, 9 ft +5%, 10 ft or more +10%.
- People: each person beyond 4 adds 0.05 ton.
- Supply registers: nominal airflow divided by 100 CFM each. Duct design sets the real count.
Where the numbers come from. The 400 to 600 square feet per ton range is the common contractor rule of thumb as reported in Manual J Load Calculations vs. Rules of Thumb (ACCA, October 20, 2016). The shift by climate zone and every nudge in the list above are conventional rules of thumb with no primary source.
The same article reports that real load calculations usually come out above 1,000 square feet per ton, which means smaller equipment than this band suggests. Oversized equipment short-cycles, removes less humidity and wears faster (Right-Sized Air Conditioners, ENERGY STAR fact sheet). The band is sized on cooling. In cold zones the heating load can set the size of a heat pump. The nominal ton and airflow figures follow the Strategy Guideline: HVAC Equipment Sizing (U.S. Department of Energy Building America, February 2012).
Efficiency tiers
The tiers are described in words because rated efficiency depends on the exact equipment match. For reference, the federal minimums in effect since January 1, 2023 are 14.3 SEER2 and 7.5 HSPF2 for split-system heat pumps nationwide, and for split-system air conditioners 13.4 SEER2 in the North and, in the Southeast and Southwest, 14.3 SEER2 under 45,000 Btu per hour or 13.8 SEER2 at or above it (U.S. Department of Energy guidance, issued October 5, 2022). ENERGY STAR lists at least 15.2 SEER2, 7.8 HSPF2 and 11.0 EER2 for split-system heat pumps (ENERGY STAR key product criteria, read 2026-11-12).
Describe the house
Square footage, stories, insulation, windows and sun. The planning load updates as you go.
Pick a system
Heat pump, AC with a furnace, dual fuel or ductless. Flip between cooling and heating and watch the airflow.
Send it
Save a link, download the system sheet, or send it to us for a real price.
About the designer.
Is the planning size the size I should buy?
No. It is a rule-of-thumb band to plan with. Equipment is sized from a room-by-room load calculation (ACCA Manual J), which accounts for your actual insulation, windows, ductwork and climate. The real size is set when the house has been looked at.
Why does bigger not mean better?
An oversized system satisfies the thermostat fast and shuts off before it has pulled the humidity out, so the house feels clammy and the equipment short-cycles. Right-sized equipment runs longer, quieter and drier.
What do the system types mean?
A heat pump heats and cools with one outdoor unit. AC with a furnace cools with electricity and heats with gas. Dual fuel pairs a heat pump with a gas furnace for the coldest days. Ductless mini-splits serve rooms directly with no ductwork.
Is anything in the designer a quote?
No. It gives a planning size and an equipment list, and a cost range only where one is shown with its published source. A real price comes after we see the house.
Rather just tell us?
Skip the designer. A few short steps and we follow up.
Something broken now? Request Service