Design Your Comfort System in 3D

Smith Climate · Tishomingo, MS

HEAT PUMPAIR HANDLER2,000 SQ FT · HEAT PUMP · 3–4 TONSPLANNING BAND · NOT A LOAD CALCULATION

Heat pump

3–4 tons

2,000 sq ft

74°F

System type

One outdoor unit heats and cools. An air handler indoors moves the air through the ducts.

Start from

Planning size

3 to 4 tons

Rule-of-thumb planning band. Not a load calculation.

A Manual J load calculation sets the real size.

Airflow
1,200 to 1,600 CFM (nominal 400 CFM per ton)
Registers
About 14 supply registers (rule of thumb)
Home
2,000
Stories
Insulation, windows, sun
System details

Single-stage equipment at the current federal minimum efficiency. On or off.

Add-ons

Add-ons are listed on the system sheet. They are not in the planning range.

Equipment list

    A starting list for the conversation. The 3D view is a schematic, not a duct design.

    Get an exact price

    How this is figured Sources and assumptions

    The planning size

    Rule-of-thumb planning band. Not a load calculation. A Manual J load calculation sets the real size.

    The band is conditioned square feet divided by a square-feet-per-ton range for your climate zone, nudged by insulation, windows, sun and ceiling height, then rounded to the half-ton sizes equipment comes in (1.5 to 5 tons). Above 5 tons it says likely two systems. One ton is 12,000 Btu per hour. Airflow is the nominal 400 CFM per ton figure.

    Climate zoneSq ft per ton used
    Zone 1 · Very hot400 to 600
    Zone 2 · Hot450 to 650
    Zone 3 · Warm500 to 700
    Zone 4 · Mixed550 to 750
    Zone 5 · Cool600 to 800
    Zone 6 · Cold650 to 850
    Zone 7 · Very cold700 to 900
    • Insulation: older or leaky +15%, average no change, tight −15%.
    • Windows: few −5%, average no change, lots of glass +10%.
    • Sun: shaded −7%, average no change, full sun +8%.
    • Ceilings: 8 ft no change, 9 ft +5%, 10 ft or more +10%.
    • People: each person beyond 4 adds 0.05 ton.
    • Supply registers: nominal airflow divided by 100 CFM each. Duct design sets the real count.

    Where the numbers come from. The 400 to 600 square feet per ton range is the common contractor rule of thumb as reported in Manual J Load Calculations vs. Rules of Thumb (ACCA, October 20, 2016). The shift by climate zone and every nudge in the list above are conventional rules of thumb with no primary source.

    The same article reports that real load calculations usually come out above 1,000 square feet per ton, which means smaller equipment than this band suggests. Oversized equipment short-cycles, removes less humidity and wears faster (Right-Sized Air Conditioners, ENERGY STAR fact sheet). The band is sized on cooling. In cold zones the heating load can set the size of a heat pump. The nominal ton and airflow figures follow the Strategy Guideline: HVAC Equipment Sizing (U.S. Department of Energy Building America, February 2012).

    Efficiency tiers

    The tiers are described in words because rated efficiency depends on the exact equipment match. For reference, the federal minimums in effect since January 1, 2023 are 14.3 SEER2 and 7.5 HSPF2 for split-system heat pumps nationwide, and for split-system air conditioners 13.4 SEER2 in the North and, in the Southeast and Southwest, 14.3 SEER2 under 45,000 Btu per hour or 13.8 SEER2 at or above it (U.S. Department of Energy guidance, issued October 5, 2022). ENERGY STAR lists at least 15.2 SEER2, 7.8 HSPF2 and 11.0 EER2 for split-system heat pumps (ENERGY STAR key product criteria, read 2026-11-12).

    01

    Describe the house

    Square footage, stories, insulation, windows and sun. The planning load updates as you go.

    02

    Pick a system

    Heat pump, AC with a furnace, dual fuel or ductless. Flip between cooling and heating and watch the airflow.

    03

    Send it

    Save a link, download the system sheet, or send it to us for a real price.

    FAQ

    About the designer.

    Is the planning size the size I should buy?

    No. It is a rule-of-thumb band to plan with. Equipment is sized from a room-by-room load calculation (ACCA Manual J), which accounts for your actual insulation, windows, ductwork and climate. The real size is set when the house has been looked at.

    Why does bigger not mean better?

    An oversized system satisfies the thermostat fast and shuts off before it has pulled the humidity out, so the house feels clammy and the equipment short-cycles. Right-sized equipment runs longer, quieter and drier.

    What do the system types mean?

    A heat pump heats and cools with one outdoor unit. AC with a furnace cools with electricity and heats with gas. Dual fuel pairs a heat pump with a gas furnace for the coldest days. Ductless mini-splits serve rooms directly with no ductwork.

    Is anything in the designer a quote?

    No. It gives a planning size and an equipment list, and a cost range only where one is shown with its published source. A real price comes after we see the house.